Division 1 Specific ecodesign requirements
United Kingdom
From 1 January 2020 solid fuel boilers shall comply with the following requirements:
- (a)
seasonal space heating energy efficiency for boilers with a rated heat output of 20 kW or less shall not be less than 75 %;
- (b)
seasonal space heating energy efficiency for boilers with a rated heat output of more than 20 kW shall not be less than 77 %;
- (c)
seasonal space heating emissions of particulate matter shall not be higher than 40 mg/m3 for automatically stoked boilers and not be higher than 60 mg/m3 for manually stoked boilers;
- (d)
seasonal space heating emissions of organic gaseous compounds shall not be higher than 20 mg/m3 for automatically stoked boilers and not be higher than 30 mg/m3 for manually stoked boilers;
- (e)
seasonal space heating emissions of carbon monoxide shall not be higher than 500 mg/m3 for automatically stoked boilers and not be higher than 700 mg/m3 for manually stoked boilers;
- (f)
seasonal space heating emissions of nitrogen oxides, expressed in nitrogen dioxide, shall not be higher than 200 mg/m3 for biomass boilers and not be higher than 350 mg/m3 for fossil fuel boilers;
These requirements shall be met for the preferred fuel and for any other suitable fuel for the solid fuel boiler.