OpenLegislation

Division IV Cleaning and decontamination procedure after a positive or doubtful result

United Kingdom

Original text. Later amendments are not shown.

When the examination of a collective or individual sample produces a positive or doubtful latex agglutination result, all material in contact with meat (blender bowl and blade, pestle, beaker, stirring rod, temperature sensor, conical filtration funnel, sieve and forceps) must be carefully decontaminated by soaking for few seconds in warm water (65 to 90 °C). Meat residues or inactivated larvae that could remain on their surface may be removed with a clean sponge and tap water. If required, a few drops of detergent can be added for degreasing equipment. It is then recommended to rinse each piece thoroughly to remove all traces of detergent.