Division 2.2.2.2 F1
United Kingdom
To check compliance with the requirements of point 2.2.1.2.4 of Annex I, a Type-0 test shall be carried out with the engine disconnected at the initial speed of 30 km/h.
On application of the control of the parking brake system, the mean fully developed deceleration and the deceleration immediately before the vehicle stops shall not be less than 1,5 m/s 2 . The same requirement applies in case of auxiliary control mentioned in point 2.2.1.2.4 of Annex I.
The test shall be carried out with the laden vehicle. The force exerted on the braking control device shall not exceed the specified values.