Division 3.1.1.1
United Kingdom
Under Type-0 conditions, the service braking system shall be tested under the conditions shown in the following table
| vmax ≤ 30 km/h | vmax > 30 km/h | |
|---|---|---|
| v | = vmax | = vmax |
| s (metres) | ≤ 0,15 v + v2/92 | ≤ 0,15 v + v2/130 |
| dm | ≥ 3,55 m/s2 | ≥ 5 m/s2 |
| F (foot operated control) | ≤ 600 N | ≤ 600 N |
| F (hand operated control) | ≤ 400 N | ≤ 400 N |
where:
vmax v s dm F
maximum design speed of the vehicle
prescribed test speed
Stopping distance
mean fully developed deceleration
force applied to the control device