Division 8.4.2 F1
United Kingdom
The results of chromatographic analysis of the test sample [E] are obtained in the form of chromatogram in which each peak is identified by its retention time RT as follows:
| Peak II: | The second peak of the chromatogram having an RT of about 12,5 minutes. |
|---|---|
| Peak III: | The third peak of the chromatogram, corresponding to the CMP, having an RT of 15,5 minutes. |
The choice of the column(s) can affect the retention times of the individual peaks considerably.
The integrator (6.11.6) automatically calculates the area A of each peak:
| A II : | area of peak II, |
|---|---|
| A III : | area of peak III, |
It is essential to examine the appearance of each chromatogram prior to quantitative interpretation, in order to detect any abnormalities due either to malfunctioning of the apparatus or the columns, or to the origin and nature of the sample analysed.
If in doubt, repeat the analysis.