Division 8.4.2 F1
United Kingdom
Before the reversed phase HPLC-analysis is carried out, the gradient conditions should be optimised. A retention time of 26 ± 2 minutes for CMP A is optimal for gradient systems having a dead volume of about 6 ml (volume from the point where the solvents come together to the volume of the injector loop, inclusive). Gradient systems having a lower dead volume (e.g. 2 ml) should use 22 minutes as an optimal retention time
Take solutions of the standard samples (5.4) without and with 50 % rennet whey.
Inject 100 μl of supernatant or filtrate (8.3.3) into the HPLC apparatus operating at the scouting gradient conditions given in Table 1.
Table 1
Scouting gradient conditions for optimisation of the chromatography
| Time (min) | Flow (ml/min) | % A | % B | Curve |
|---|---|---|---|---|
| Initial | 1,0 | 90 | 10 | * |
| 27 | 1,0 | 60 | 40 | linear |
| 32 | 1,0 | 10 | 90 | linear |
| 37 | 1,0 | 10 | 90 | linear |
| 42 | 1,0 | 90 | 10 | linear |
Comparison of the two chromatograms should reveal the location of the peak of CMP Α .
Using the formula given below, the initial solvent composition to be used for the normal gradient (see 8.4.3) can be calculated % B = 10 – 2,5 + (13,5 + (RT cmpA – 26) / 6) * 30 / 27 % B = 7,5 + (13,5 + (RT cmpA – 26) / 6) * 1,11
Where:
retention time of CMP Α in the scouting gradient
the initial % B of the scouting gradient
% B at midpoint minus % B at initial in the normal gradient
midpoint time of the scouting gradient
required retention time of CMP Α
ratio of slopes of the scouting and normal gradient
% B at initial minus % B at 27 minutes in the scouting gradient
run-time of the scouting gradient.