This event shall be triggered, while not in calibration mode , when the VU detects a discrepancy of more than 1 minute between the time of the vehicle unit’s time measurement function and the time originating from the GNSS receiver. This event is recorded together with the internal clock value of the vehicle unit and comes together with an automatic time adjustment. After a time conflict event has been triggered, the VU will not generate other time conflict events for the next 12 hours. This event shall not be triggered in cases where no valid GNSS signal was detectable by the GNSS receiver for 30 days or more.

Annotations

Textual amendments

F1

Substituted by Commission Implementing Regulation (EU) 2018/502 of 28 February 2018 amending Implementing Regulation (EU) 2016/799 laying down the requirements for the construction, testing, installation, operation and repair of tachographs and their components (Text with EEA relevance).

Notes on Annex I C

Modifications

C1

Annex 1C modified (21.8.2023) by The Drivers’ Hours and Tachographs (Amendment) Regulations 2023 (S.I. 2023/739), regs. 1(1), 3, Sch.