Division 3.3.1.3
United Kingdom
Pollution control system parameters:
- (a)
Catalytic converters and particulate filters:
number of catalytic converters, filters and elements,
size of catalytic converters and filters (volume of monolith ± 10 %),
type of catalytic activity (oxidizing, three-way, lean NOx trap, SCR, lean NOx catalyst or other),
precious metal load (identical or higher),
precious metal type and ratio (± 15 %),
substrate (structure and material),
cell density,
temperature variation of no more than 50 K at the inlet of the catalytic converter or filter. This temperature variation shall be checked under stabilized conditions at a vehicle speed of 120 km/h and the load setting of the type 1 test.
- (b)
Air injection:
with or without
type (pulsair, air pumps, other(s))
- (c)
EGR:
with or without
type (cooled or non-cooled, active or passive control, high pressure or low pressure).