Division 3.4.2.4 Figure A5/6 of this Sub-Annex shows an example of a calibration set-up. Variations are permissible, provided that the approval authority approves them as being of comparable accuracy. If the set-up shown in Figure A5/6 is used, the following data shall be found within the limits of accuracy given:
Barometric pressure (corrected), Pb ± 0,03 kPa
Ambient temperature, T F1± 0,2 °C
Air temperature at LFE, ETI ± 0,15 °C
Pressure depression upstream of LFE, EPI ± 0,01 kPa
Pressure drop across the LFE matrix, EDP ± 0,0015 kPa
Air temperature at CVS pump inlet, PTI ± 0,2 °C
Air temperature at CVS pump outlet, PTO ± 0,2 °C
Pressure depression at CVS pump inlet, PPI ± 0,22 kPa
Pressure head at CVS pump outlet, PPO ± 0,22 kPa
Pump revolutions during test period, n ± 1 min–1
Elapsed time for period (minimum 250 s), t ± 0,1 s