Division 3.4.4.2.1 The airflow rate, Qssv, at each restriction setting (minimum 16 settings) shall be calculated in standard m3/s from the flow meter data using the manufacturer's prescribed method. The discharge coefficient, Cd, shall be calculated from the calibration data for each setting using the following equation:

Original text. Later amendments are not shown.

Cd=QSSVd2V× pp×1T×r1,426p− r1,718p×11− r4D× r1,426p

where:

Qssv
  • is the airflow rate at standard conditions (101,325 kPa, 273,15 K (0 °C)), m3/s;

  • T
  • is the temperature at the venturi inlet, Kelvin (K);

  • dV
  • is the diameter of the SSV throat, m;

  • rp
  • is the ratio of the SSV throat pressure to inlet absolute static pressure, 1−Δppp;

  • rD
  • is the ratio of the SSV throat diameter, dV, to the inlet pipe inner diameter D;

  • Cd
  • is the discharge coefficient of the SSV;

  • Pp
  • is the absolute pressure at venturi inlet, kPa.

  • To determine the range of subsonic flow, Cd shall be plotted as a function of Reynolds number Re at the SSV throat. The Reynolds number at the SSV throat shall be calculated using the following equation:

    Re=A1×QSSVdV× μ

    where:

    μ=b× T1.5S+ T
    A1
  • is 25.55152 in SI, 1m3minsmmm;

  • Qssv
  • is the airflow rate at standard conditions (101,325 kPa, 273,15 K (0 °C)), m3/s;

  • dv
  • is the diameter of the SSV throat, m;

  • μ
  • is the absolute or dynamic viscosity of the gas, kg/ms;

  • b
  • is 1,458 × 106 (empirical constant), kg/ms K0.5;

  • S
  • is 110,4 (empirical constant), Kelvin (K).