Division 3.4.5.6
F1Measurements for flow calibration of the ultrasonic flow meter are required and the following data (in the case that a laminar flow element is used) shall be found within the limits of accuracy given:
Barometric pressure (corrected), Pb ± 0,03 kPa,
LFE air temperature, flow meter, ETI ± 0,15 °C,
Pressure depression upstream of LFE, EPI ± 0,01 kPa,
Pressure drop across (EDP) LFE matrix ± 0,0015 kPa,
Air flow, Qs ± 0,5 per cent,
UFM inlet depression, Pact ± 0,02 kPa,
Temperature at UFM inlet, Tact± 0,2 °C.