Division 3.4.5.8

Original text. Later amendments are not shown.

The data recorded during the calibration shall be used in the following calculations. The air flow rate Qs at each test point shall be calculated from the flow meter data using the manufacturer's prescribed method.

Kv=QreferenceQs

where:

Qs
  • is the air flow rate at standard conditions (101,325 kPa, 273,15 K (0 °C)), m3/s;

  • Qreference
  • is the air flow rate of the calibration flow meter at standard conditions (101,325 kPa, 273,15 K (0 °C)), m3/s;

  • Kv
  • is the calibration coefficient.

  • For UFM systems without a heat exchanger, Kv shall be plotted as a function of Tact.

    The maximum variation in Kv shall not exceed 0,3 per cent of the arithmetic average Kv value of all the measurements taken at the different temperatures.