OpenLegislation

Division 5.7.2.2 The test aerosol for these measurements shall be solid particles of 30, 50 and 100 nm electrical mobility diameter and a minimum concentration of 5 000 particles per cm3 at the VPR inlet. As an option, a polydisperse aerosol with an electrical mobility median diameter of 50 nm may be used for validation. The test aerosol shall be thermally stable at the VPR operating temperatures. Particle number concentrations shall be measured upstream and downstream of the components.

Original text. Later amendments are not shown.

The particle concentration reduction factor for each monodisperse particle size, fr (di), shall be calculated using the following equation:

frdi=NindiNoutdi

where:

Nin(di)
  • is the upstream particle number concentration for particles of diameter di;

  • Nout(di)
  • is the downstream particle number concentration for particles of diameter di;

  • di
  • is the particle electrical mobility diameter (30, 50 or 100 nm).