Division 3.1.1 F1
Calculation of the regeneration factor Ki for each compound i considered.
The manufacturer may elect to determine for each compound independently either additive offsets or multiplicative factors.
Ki factor Ki offset
Ki = Mpi – Msi
Msi, Mpi and Ki results, and the manufacturer's choice of type of factor shall be recorded. The Ki result shall be included in all relevant test reports. Msi, Mpi and Ki results shall be included in all relevant test sheets.
Ki may be determined following the completion of a single regeneration sequence comprising measurements before, during and after regeneration events as shown in Figure A6.App1/1.