OpenLegislation

Division 3.1.1 F1

Original text. Later amendments are not shown.

Calculation of the regeneration factor Ki for each compound i considered.

The manufacturer may elect to determine for each compound independently either additive offsets or multiplicative factors.

Ki factor
  • Ki=MpiMsi

  • Ki offset
  • Ki = Mpi – Msi

  • Msi, Mpi and Ki results, and the manufacturer's choice of type of factor shall be recorded. The Ki result shall be included in all relevant test reports. Msi, Mpi and Ki results shall be included in all relevant test sheets.

    Ki may be determined following the completion of a single regeneration sequence comprising measurements before, during and after regeneration events as shown in Figure A6.App1/1.

    Annotations

    Textual amendments

    F1

    Substituted by Commission Regulation (EU) 2018/1832 of 5 November 2018 amending Directive 2007/46/EC of the European Parliament and of the Council, Commission Regulation (EC) No 692/2008 and Commission Regulation (EU) 2017/1151 for the purpose of improving the emission type approval tests and procedures for light passenger and commercial vehicles, including those for in-service conformity and real-driving emissions and introducing devices for monitoring the consumption of fuel and electric energy (Text with EEA relevance).