Division 2.1.3.1.2 F1
Dilution air background particulate mass level shall be determined by passing filtered dilution air through the particulate background filter. This shall be drawn from a point immediately downstream of the dilution air filters. Background levels in μg/m3 shall be determined as a rolling arithmetic average of at least 14 measurements with at least one measurement per week.