Road load and dynamometer settings shall be as specified in Sub-Annex 4, including the requirement for the room temperature to be at 23 °C.

To take account of the difference in air density at 14 °C when compared to the air density at 20 °C, the chassis dynamometer shall be set as specified in paragraphs 7. and 8. of Sub-Annex 4 with the exception that f2_TReg from the following equation shall be used as the target coefficient Ct.

f2_TReg = f2 × (Tref + 273)/(Treg + 273)

where:

f2
  • is the second order road load coefficient, at reference conditions, N/(km/h)2;

  • Tref
  • is the road load reference temperature as specified in paragraph 3.2.10. of this Annex, C;

  • Treg
  • is the regional temperature, as defined in paragraph 3.1.1., C.

  • In the case that a valid chassis dynamometer setting of the 23 °C test is available, the second order chassis dynamometer coefficient of Cd shall be adapted in accordance with the following equation:

    Cd_Treg = Cd + (f2_TReg – f2)

    Annotations

    Textual amendments

    F1

    Substituted by Commission Regulation (EU) 2018/1832 of 5 November 2018 amending Directive 2007/46/EC of the European Parliament and of the Council, Commission Regulation (EC) No 692/2008 and Commission Regulation (EU) 2017/1151 for the purpose of improving the emission type approval tests and procedures for light passenger and commercial vehicles, including those for in-service conformity and real-driving emissions and introducing devices for monitoring the consumption of fuel and electric energy (Text with EEA relevance).