OpenLegislation

Division 3.4 F1

Original text. Later amendments are not shown.

The Pm,j values shall be calculated for each individual phase of the WLTC using the following equation:

Pm,j=∑tendt0Pmi∕n

where:

Pm,j
  • is the average actual/measured power of the considered phase j, kW;

  • Pmi
  • is the actual/measured power during the period from (i – 1) to (i), kW;

  • t0
  • is the time at the beginning of the considered phase j, s;

  • tend
  • is the time at the end of the considered phase j, s;

  • n
  • is the number of time steps in the considered phase;

  • j
  • is the index number for the considered phase.

  • Annotations

    Textual amendments

    F1

    Inserted by Commission Regulation (EU) 2018/1832 of 5 November 2018 amending Directive 2007/46/EC of the European Parliament and of the Council, Commission Regulation (EC) No 692/2008 and Commission Regulation (EU) 2017/1151 for the purpose of improving the emission type approval tests and procedures for light passenger and commercial vehicles, including those for in-service conformity and real-driving emissions and introducing devices for monitoring the consumption of fuel and electric energy (Text with EEA relevance).