In the next step, a second POVERRUN,2 is calculated following the equation:

POVERRUN,2 = – Dv,1/ kv,1

where:

POVERRUN,2
  • is the second overrun power, kW;

  • kv,1
  • is the slope of the Veline equation-1, g CO2/kWs;

  • Dv,1
  • is the constant of the Veline equation-1, g CO2/s.

  • Annotations

    Textual amendments

    F1

    Inserted by Commission Regulation (EU) 2018/1832 of 5 November 2018 amending Directive 2007/46/EC of the European Parliament and of the Council, Commission Regulation (EC) No 692/2008 and Commission Regulation (EU) 2017/1151 for the purpose of improving the emission type approval tests and procedures for light passenger and commercial vehicles, including those for in-service conformity and real-driving emissions and introducing devices for monitoring the consumption of fuel and electric energy (Text with EEA relevance).