Division 4.1 F1
To apply the correction function, the electric energy change ΔTREESS,j of a period j of all REESSs shall be calculated from the measured current and the nominal voltage:
where:
is the electric energy change of REESS i during the considered period j, Wh;
and:
where:
is the nominal REESS voltage determined in accordance with IEC 60050-482, V;
is the electric current of REESS i during the considered period j, determined in accordance with paragraph 2. of this Appendix, A;
is the time at the beginning of the considered period j, s;
is the time at the end of the considered period j, s.
is the index number of the considered REESS;
is the total amount of REESS;
is the index number for the considered period, where a period shall be any applicable cycle phase, combination of cycle phases and the applicable total cycle;
is the conversion factor from Ws to Wh.