The volume shall be calculated using the following equation:

V=V0× N

where:

V
  • is the volume of the diluted gas, in litres per test (prior to correction);

  • V0
  • is the volume of gas delivered by the positive displacement pump in testing conditions, litres per pump revolution;

  • N
  • is the number of revolutions per test.

    1. 2.2.1.1Correcting the volume to standard conditions