OpenLegislation

Division 3.2.1

Original text. Later amendments are not shown.

Mass emissions of gaseous compounds per cycle phase shall be calculated using the following equations:

Mi,phase=Vmix,phase× ρi× KHphase× Ci,phase× 10− 6dphase

where:

Mi
  • is the mass emission of compound i per test or phase, g/km;

  • Vmix
  • is the volume of the diluted exhaust gas per test or phase expressed in litres per test/phase and corrected to standard conditions (273,15 K (0 °C) and 101,325 kPa);

  • ρi
  • is the density of compound i in grams per litre at standard temperature and pressure (273,15 K (0 °C) and 101,325 kPa);

  • KH
  • is a humidity correction factor applicable only to the mass emissions of oxides of nitrogen, NO2 and NOx, per test or phase;

  • Ci
  • is the concentration of compound i per test or phase in the diluted exhaust gas expressed in ppm and corrected by the amount of compound i contained in the dilution air;

  • d
  • is the distance driven over the applicable WLTC, km;

  • n
  • is the number of phases of the applicable WLTC.

    1. 3.2.1.1Division 3.2.1.1
    2. 3.2.1.2Calculation of the NOx humidity correction factor