Division 4.2.1.2.1 Stepwise procedure for calculating the final test fuel consumption results of the charge-sustaining Type 1 test for NOVC-FCHVsF1
The results shall be calculated in the order described in the Tables A8/7. All applicable results in the column ‘Output’ shall be recorded. The column ‘Process’ describes the paragraphs to be used for calculation or contains additional calculations.
For the purpose of this table, the following nomenclature within the equations and results is used:
complete applicable test cycle;
every applicable cycle phase;
charge-sustaining
Table A8/7
Calculation of final charge-sustaining fuel consumption for NOVC-FCHVs
| Source | Input | Process | Output | Step no. |
|---|---|---|---|---|
| Appendix 7 of this Sub-Annex. | Non-balanced charge-sustaining fuel consumption FCCS,nb,kg/100 km | Charge-sustaining fuel consumption according to paragraph 2.2.6. of Appendix 7. to this Sub-Annex | FCCS,c,1, kg/100 km; | 1 |
| Output from step no. 1 of this Table. | FCCS,c,1, kg/100 km; | REESS electric energy change correction Sub-Annex 8, paragraphs 4.2.1.2.2. to 4.2.1.2.3. inclusive of this Sub-Annex | FCCS,c,2, kg/100 km; | 2 |
| Output from step No. 2 of this table. | FCCS,c,2, kg/100 km. | FCCS,c,3 = FCCS,c,2 | FCCS,c,3, kg/100 km. | 3 Result of a single test. |
| Output from step No. 3 of this table. | For every test: FCCS,c,3, kg/100 km. | Averaging of tests and declared value according to paragraphs 1.2. to 1.2.3. inclusive of Sub-Annex 6. | FCCS,c,4, kg/100 km. | 4 |