Division 4.3.3.1 Determination of cycle-specific electric energy consumption
The electric energy consumption based on the recharged electric energy from the mains and the equivalent all-electric range shall be calculated using the following equation:
where:
EC EAC EAER
is the electric energy consumption of the applicable WLTP test cycle based on the recharged electric energy from the mains and the equivalent all-electric range, Wh/km;
is the recharged electric energy from the mains according to paragraph 3.2.4.6. of this Sub-Annex, Wh;
is the equivalent all-electric range according to paragraph 4.4.4.1. of this Sub-Annex, km.