OpenLegislation

Division 4.3.4.2 Electric energy consumption determination of the applicable WLTP test cycle

Original text. Later amendments are not shown.

The electric energy consumption of the applicable WLTP test cycle based on the recharged electric energy from the mains and the pure electric range shall be calculated using the following equation:

ECWLTC=EACPERWLTC

where:

ECWLTC
  • is the electric energy consumption of the applicable WLTP test cycle based on the recharged electric energy from the mains and the pure electric range for the applicable WLTP test cycle, Wh/km;

  • EAC
  • is the recharged electric energy from the mains according to paragraph 3.4.4.3. of this Sub-Annex, Wh;

  • PERWLTC
  • is the pure electric range for the applicable WLTP test cycle as calculated according to paragraph 4.4.2.1.1. or paragraph 4.4.2.2.1. of this Sub-Annex, depending on the PEV test procedure that must be used, km.