OpenLegislation

Division 4.5.6.1 Individual utility factor-weighted charge-depleting electric energy consumption based on the recharged electric energy from the mains for OVC-HEVs

Original text. Later amendments are not shown.

The utility factor-weighted charge-depleting electric energy consumption based on the recharged electric energy from for an individual vehicle shall be calculated using the following equation:

ECAC–ind,CD=ECAC–L,CD+ Kind×ECAC–H,CD− ECAC–L,CD

where:

ECAC–ind,CD
  • is the utility factor-weighted charge-depleting electric energy consumption based on the recharged electric energy from the mains for an individual vehicle, Wh/km;

  • ECAC–L,CD
  • is the utility factor-weighted charge-depleting electric energy consumption based on the recharged electric energy from the mains for vehicle L, Wh/km;

  • ECAC–H,CD
  • is the utility factor-weighted charge-depleting electric energy consumption based on the recharged electric energy from the mains for vehicle H, Wh/km;

  • Kind
  • is the interpolation coefficient for the considered individual vehicle for the applicable WLTP test cycle