Division 4.5.7.3 Individual equivalent all-electric range for OVC-HEVs

Original text. Later amendments are not shown.

The equivalent all-electric range for an individual vehicle shall be calculated using the following equation:

EAERind,p=EAERL,p+ Kind,p×EAERH,p− EAERL,p

where:

EAERind,p
  • is the equivalent all-electric range for an individual vehicle for the considered period p, km;

  • EAERL,p
  • is the equivalent all-electric range for vehicle L for the considered period p, km;

  • EAERH,p
  • is the equivalent all-electric range for vehicle H for the considered period p, km;

  • Kind,p
  • is the interpolation coefficient for the considered individual vehicle for period p;

  • p
  • is the index of the individual period within the applicable test cycle.

  • The considered periods shall be the low-phase, mid-phase, high-phase, extra high-phase, applicable WLTP city test cycle and the applicable WLTP test cycle.