Division 1.2.2 Charge-sustaining fuel energy for NOVC-FCHVs
The charge-sustaining energy content of the consumed fuel for NOVC-FCHVs shall be calculated using the following equation:
Efuel,CS 121 FCCS,nb dCS
is the charge-sustaining energy content of the consumed fuel of the applicable WLTP test cycle of the charge-sustaining Type 1 test, Wh;
is the lower heating value of hydrogen, MJ/kg;
is the non-balanced charge-sustaining fuel consumption of the charge-sustaining Type 1 test, not corrected for the energy balance, determined according to Table A8/7, step no.1, kg/100 km;
is the distance driven over the corresponding applicable WLTP test cycle, km;
conversion factor to Wh.
F1Table A8.App2/1
RCB correction criteria thresholds
| Applicable Type 1 test cycle | Low + Medium | Low + Medium + High | Low + Medium + High + Extra High |
|---|---|---|---|
| Thresholds for correction criterion c | 0,015 | 0,01 | 0,005 |