Division 3 For the calculation of a fractional utility factor UFj for the weighting of period j, the following equation shall be applied by using the coefficients from Table A8.App5/1.F1
where:
UFj dj Ci dn k j i
utility factor for period j;
measured distance driven at the end of period j, km;
ith coefficient (see Table A8.App5/1);
normalized distance (see Table A8.App5/1), km;
number of terms and coefficients in the exponent;
number of period considered;
number of considered term/coefficient;
sum of calculated utility factors up to period (j – 1).
| Table A8.App5/1 | |
| Parameters for the determination of fractional UFs | |
| Parameter | Value |
|---|---|
| dn | 800 km |
| C1 | 26,25 |
| C2 | – 38,94 |
| C3 | – 631,05 |
| C4 | 5 964,83 |
| C5 | – 25 095 |
| C6 | 60 380,2 |
| C7 | – 87 517 |
| C8 | 75 513,8 |
| C9 | – 35 749 |
| C10 | 7 154,94 |