Division 2.1.5.1 F1
The balance used for fuel consumption measurement shall meet the specification of Table A8.App7/1.
Table A8.App7/1
Analytical balance verification criteria
Fuel consumption (REESS charge balance = 0) during the test, in mass, standard deviation. | ||
| Measurement system | Resolution | Precision |
|---|---|---|
| Balance | 0,1 g maximum | ± 0,02 maximumf1 |
Annotations
Textual amendments
Footnotes
- f1
Fuel consumption (REESS charge balance = 0) during the test, in mass, standard deviation.