Division 5.5.1 F1
Only vehicles that are identical with respect to the characteristics listed in (a), (c) and (d), technically equivalent with respect to the characteristics listed in (b) and similar or, where applicable, within the stated tolerance regarding the characteristics listed in (e) and (f) may be part of the same evaporative emission family:
- (a)
Fuel tank system material and construction;
- (b)
Vapour hose material, fuel line material and connection technique;
- (c)
Sealed tank or non-sealed tank system;
- (d)
Fuel tank relief valve setting (air ingestion and relief);
- (e)
Canister butane working capacity (BWC300) within a 10 per cent range of the highest value (for canisters with the same type of charcoal, the volume of charcoal shall be within 10 per cent of that for which the BWC300 was determined);
- (f)
Purge control system (for example, type of valve, purge control strategy).