Division 4.3.5.2.1 Definition of target engine speed setpoints
United Kingdom
The 10 target engine speed setpoints are defined by 4 base target engine speed setpoints and 6 additional target engine speed setpoints.
The engine speeds nidle, nlo, npref, n95h and nhi shall be determined from the engine full load curve of the CO2-parent engine of the engine CO2-family defined in accordance with Appendix 3 to this Annex and recorded in accordance with paragraph 4.3.1 by applying the definitions of characteristic engine speeds in accordance with paragraph 7.4.6. of Annex 4 to UN/ECE Regulation 49 Rev.06.
The engine speed n57 shall be determined by the following equation:
n57 = 0,565 × (0,45 × nlo + 0,45 × npref + 0,1 × nhi – nidle) × 2,0327 + nidle
The 4 base target engine speed setpoints are defined as follows:
- (1)
Base engine speed 1: nidle
- (2)
Base engine speed 2: nA = n57 – 0,05 × (n95h – nidle)
- (3)
Base engine speed 3: nB = n57 + 0,08 × (n95h – nidle)
- (4)
Base engine speed 4: n95h
The potential distances between the speed setpoints shall be determined by the following equations:
- (1)
dnidleA_44 = (nA – nidle) / 4
- (2)
dnB95h_44 = (n95h – nB) / 4
- (3)
dnidleA_35 = (nA – nidle) / 3
- (4)
dnB95h_35 = (n95h – nB) / 5
- (5)
dnidleA_53 = (nA – nidle) / 5
- (6)
dnB95h_53 = (n95h – nB) / 3
The absolute values of potential deviations between the two sections shall be determined by the following equations:
- (1)
dn44 = ABS(dnidleA_44 – dnB95h_44)
- (2)
dn35 = ABS(dnidleA_35 – dnB95h_35)
- (3)
dn53 = ABS(dnidleA_53 – dnB95h_53)
F1The 6 additional target engine speed setpoints shall be determined in accordance with the following provisions:
- (1)
If dn 44 is smaller than or equal to (dn 35 + 5) and also smaller than or equal to (dn 53 + 5), the 6 additional target engine speeds shall be determined by dividing each of the two ranges, one from n idle to n A and the other from n B to n 95h , into 4 equidistant sections.
- (2)
If (dn 35 + 5) is smaller than dn 44 and also dn 35 is smaller than dn 53 , the 6 additional target engine speeds shall be determined by dividing the range from n idle to n A into 3 equidistant sections and the range from n B to n 95h , into 5 equidistant sections.
- (3)
If (dn 53 + 5) is smaller than dn 44 and also dn 53 is smaller than dn 35 , the 6 additional target engine speeds shall be determined by dividing the range from n idle to n A into 5 equidistant sections and the range from n B to n 95h , into 3 equidistant sections.
Figure 1 exemplarily illustrates the definition of the target engine speed setpoints according to subpoint (1) above.
Figure 1
Definition of speed setpoints