Division 3.3.7 Measurement signals and data recording
United Kingdom
At least the following signals shall be recorded during the measurement:
- (1)
Input and output torques [Nm]
- (2)
Input and output rotational speeds [rpm]
- (3)
Ambient temperature [°C]
- (4)
Oil temperature [°C]
If the transmission is equipped with a shift and/or clutch system that is controlled by hydraulic pressure or with a mechanically driven smart lubrication system, additionally to be recorded:
- (5)
Oil pressure [kPa]
If the transmission is equipped with transmission electric auxiliary, additionally to be recorded:
- (6)
Voltage of transmission electric auxiliary [V]
- (7)
Current of transmission electric auxiliary [A]
For differential measurements for compensation of influences by test rig setup, additionally to be recorded:
- (8)
Test rig bearing temperature [°C]
The sampling and recording rate shall be 100 Hz or higher.