OpenLegislation

Division 3.3.7 Measurement signals and data recording

United Kingdom

Original text. Later amendments are not shown.

At least the following signals shall be recorded during the measurement:

  1. (1)

    Input and output torques [Nm]

  2. (2)

    Input and output rotational speeds [rpm]

  3. (3)

    Ambient temperature [°C]

  4. (4)

    Oil temperature [°C]

If the transmission is equipped with a shift and/or clutch system that is controlled by hydraulic pressure or with a mechanically driven smart lubrication system, additionally to be recorded:

  1. (5)

    Oil pressure [kPa]

If the transmission is equipped with transmission electric auxiliary, additionally to be recorded:

  1. (6)

    Voltage of transmission electric auxiliary [V]

  2. (7)

    Current of transmission electric auxiliary [A]

For differential measurements for compensation of influences by test rig setup, additionally to be recorded:

  1. (8)

    Test rig bearing temperature [°C]

The sampling and recording rate shall be 100 Hz or higher.

A low pass filter shall be applied to avoid measurement errors.