Division 3.3.9 Measurement uncertainty
United Kingdom
The part of the calculated total uncertainty UT,loss exceeding 5 % of Tloss or 1 Nm (ΔUT,loss ), whichever value of ΔUT,loss is smaller, shall be added to Tloss for the reported torque loss Tloss,rep . If UT,loss is smaller than 5 % of Tloss or 1 Nm, then Tloss,rep = Tloss .
Tloss,rep = Tloss + MAX (0, ΔUT,loss )
ΔUT,loss = MIN ((UT,loss – 5 % * Tloss ), (UT,loss – 1 Nm))
For each measurement set, the total uncertainty UT,loss of the torque loss shall be calculated based on the following parameters:
- (1)
Temperature effect
- (2)
Parasitic loads
- (3)
Calibration error (incl. sensitivity tolerance, linearity, hysteresis and repeatability)
The total uncertainty of the torque loss (UT,loss ) is based on the uncertainties of the sensors at 95 % confidence level. The calculation shall be done as the square root of the sum of squares (‘Gaussian law of error propagation’).
wpara = senspara * ipara
where:
Measured torque loss (uncorrected) [Nm]
Reported torque loss (after uncertainty correction) [Nm]
Total expanded uncertainty of torque loss measurement at 95 % confidence level [Nm]
Uncertainty of input/output torque loss measurement separately for input and output torque sensor[Nm]
Gear ratio [-]
Uncertainty by temperature influence on current torque signal [Nm]
Temperature influence on current torque signal per Kref, declared by sensor manufacturer [%]
Uncertainty by temperature influence on zero torque signal (related to nominal torque) [Nm]
Temperature influence on zero torque signal per Kref (related to nominal torque), declared by sensor manufacturer [%]
Reference temperature span for uTKC and uTK0, wtk0 and wtkc, declared by sensor manufacturer [K]
Difference in sensor temperature between calibration and measurement [K]. If the sensor temperature cannot be measured, a default value of ΔK = 15 K shall be used.
Current/measured torque value at torque sensor [Nm]
Nominal torque value of torque sensor [Nm]
Uncertainty by torque sensor calibration [Nm]
Relative calibration uncertainty (related to nominal torque) [%]
calibration advancement factor (if declared by sensor manufacturer, otherwise = 1)
Uncertainty by parasitic loads [Nm]
senspara * ipara
Relative influence of forces and bending torques caused by misalignment [%]
Maximum influence of parasitic loads for specific torque sensor declared by sensor manufacturer [%]; if no specific value for parasitic loads is declared by the sensor manufacturer, the value shall be set to 1,0 %
Maximum influence of parasitic loads for specific torque sensor depending on test setup (A/B/C, as defined below).
A) 10 % in case of bearings isolating the parasitic forces in front of and behind the sensor and a flexible coupling (or cardan shaft) installed functionally next to the sensor (downstream or upstream); furthermore, these bearings can be integrated in a driving/braking machine (e.g. electric machine) and/or in the transmission as long as the forces in the machine and/or transmission are isolated from the sensor. See figure 3.
Figure 3
Test setup A for Option 3
B) 50 % in case of bearings isolating the parasitic forces in front of and behind the sensor and no flexible coupling installed functionally next to the sensor; furthermore, these bearings can be integrated in a driving/braking machine (e.g. electric machine) and/or in the transmission as long as the forces in the machine and/or transmission are isolated from the sensor. See figure 4.
Figure 4
Test setup B for Option 3
C) 100 % for other setups