Division 4.3.3.2
United Kingdom
Output torque steps to be measured:
250 Nm < Tout < 1 000 Nm 1 000 Nm ≤ Tout ≤ 2 000 Nm 2 000 Nm ≤ Tout ≤ 10 000 Nm Tout > 10 000 Nm
250 Nm steps
500 Nm steps
1 000 Nm steps
2 000 Nm steps
If the maximum input torque is limited by the manufacturer, the last torque step to be measured is the one below this maximum without consideration of any losses. In that case an extrapolation of the torque loss shall be applied up to the torque corresponding to the manufacturer's limitation with the linear regression based on the torque steps of the corresponding speed step.