Division 4.4.7 Assessment of total uncertainty of the torque loss
United Kingdom
In the case the calculated uncertainties UT,in/out are below the following limits, the reported torque loss Tloss,rep shall be regarded as equal to the measured torque loss Tloss .
UT,in : 7,5 Nm or 0,25 % of the measured torque, whichever allowed uncertainty value is higher
UT,out : 15 Nm or 0,25 % of the measured torque, whichever allowed uncertainty value is higher
In the case of higher calculated uncertainties, the part of the calculated uncertainty exceeding the above specified limits shall be added to Tloss for the reported torque loss Tloss,rep as follows:
If the limits of UT,in are exceeded:
-
Tloss,rep = Tloss + ΔUTin
-
ΔUT,in = MIN((UT,in – 0,25 % * Tc) or (UT,in – 7,5 Nm))
If limits of UT,out out are exceeded:
-
Tloss,rep = Tloss + ΔUT,out/igear
-
ΔUT,out = MIN((UT,out – 0,25 % * Tc) or (UT,out – 15Nm))
where:
Uncertainty of input/output torque loss measurement separately for input and output torque; [Nm]
Axle gear ratio [-]
The part of the calculated uncertainty exceeding the specified limits