The following 1-step formula set out in equation (7-20) can be used for the calculation of the wet exhaust gas mass flow rate qm ew, i [kg/s]:

q m ew, i = q m f, i × 1,4 × w 2 C 1,0828 × w C + k fd × f c f c 1 + H a 1000 + 1 (7-20)

with the carbon factor f c [-] given by:

f c = 0,5441 × c CO2d − c CO2d,a + c COd 18522 + c HCw 17355 (7-21)

Where:

qm f, i
  • instantaneous fuel mass flow rate [kg/s]

  • F1w C
  • carbon content of fuel [% mass] (see equation (7-82) of point 3.3.3.1 or table 7.3)

  • H a
  • intake air humidity [g H2O/kg dry air]

  • k fd
  • combustion additional volume on a dry basis [m3/kg fuel]

  • c CO2d
  • dry CO2 concentration in the raw exhaust gas [%]

  • c CO2d,a
  • dry CO2 concentration in the ambient air [%]

  • c COd
  • dry CO concentration in the raw exhaust gas [ppm]

  • c HCw
  • wet HC concentration in the raw exhaust gas [ppm]

  • and factor k fd [m3/kg fuel] that is calculated by means of equation (7-22) on a dry basis by subtracting the water formed by combustion from k f:

    k fd = k f – 0,11118 · w H (7-22)

    where:

    k f
  • fuel specific factor of equation (7-5) [m3/kg fuel]

  • w H
  • hydrogen content of fuel [% mass]

  • Annotations

    Textual amendments

    F1

    Substituted by Commission Delegated Regulation (EU) 2018/989 of 18 May 2018 amending and correcting Delegated Regulation (EU) 2017/654 supplementing Regulation (EU) 2016/1628 of the European Parliament and of the Council with regard to technical and general requirements relating to emission limits and type-approval for internal combustion engines for non-road mobile machinery (Text with EEA relevance).