Division 2.2.4.2 CFV-CVS system

United Kingdom

Original text. Later amendments are not shown.

The mass flow over the cycle m ed [g/test] shall be calculated by means of equation (7-37), if the temperature of the diluted exhaust gas is kept within ± 11 K over the cycle by using a heat exchanger:

m ed = 1,293 × t × K V × p p T 0,5 (7-37)

Where:

t
  • cycle time [s]

  • K V
  • calibration coefficient of the critical flow venturi for standard conditions K × m 4 × s ∕ kg

  • p p
  • absolute pressure at venturi inlet [kPa]

  • T
  • absolute temperature at venturi inlet [K]

  • 1,293 kg/m3
  • air density at 273,15 K and 101,325 kPa

  • If a system with flow compensation is used (i.e. without heat exchanger), the mass of the diluted exhaust gas m ed, i [kg] during the time interval shall be calculated by means of equation (7-38):

    m ed, i = 1,293 × Δ t i × K V × p p T 0,5 (7-38)

    where:

    Δti
  • time interval of the test [s]

  • K V
  • calibration coefficient of the critical flow venturi for standard conditions K × m 4 × s ∕ kg

  • p p
  • absolute pressure at venturi inlet [kPa]

  • T
  • absolute temperature at venturi inlet [K]

  • 1,293 kg/m3
  • air density at 273,15 K and 101,325 kPa