Division 2.2.4.3 SSV-CVS system
United Kingdom
The diluted exhaust gas mass over the cycle m ed [kg/test] shall be calculated by means of equation (7-39), if the temperature of the diluted exhaust gas is kept within ± 11 K over the cycle by using a heat exchanger:
| m ed = 1,293 · qV SSV · Δt | (7-39) |
Where:
air density at 273,15 K and 101,325 kPa
cycle time [s]
air flow rate at standard conditions (101,325 kPa, 273,15 K) [m3/s]
with
| (7-40) |
Where:
collection of constants and units conversions = 0,0056940
diameter of the SSV throat [mm]
discharge coefficient of the SSV [-]
absolute pressure at venturi inlet [kPa]
temperature at the venturi inlet [K]
ratio of the SSV throat to inlet absolute static pressure, [-]
ratio of the SSV throat diameter to the inlet pipe inner diameter [-]
If a system with flow compensation is used (i.e. without heat exchanger), the mass of the diluted exhaust gas m ed, i [kg] during the time interval shall be calculated by means of equation (7-41):
| m ed, i = 1,293 · qV SSV · Δt i | (7-41) |
Where:
air density at 273,15 K and 101,325 kPa
time interval [s]
volumetric flow rate of the SSV [m3/s]