OpenLegislation

Division 2.3.1.2 Full flow dilution system

United Kingdom

Original text. Later amendments are not shown.

The mass emission shall be calculated by means of equation (7-48):

m PM = m f m sep × m ed 1000 (7-48)

where:

m f
  • is the particulate mass sampled over the cycle [mg]

  • m sep
  • is the mass of diluted exhaust gas passing the particulate collection filters [kg]

  • m ed
  • is the mass of diluted exhaust gas over the cycle [kg]

  • with

    m sep = m set – m ssd (7-49)

    Where:

    m set
  • mass of double diluted exhaust gas through particulate filter [kg]

  • m ssd
  • mass of secondary dilution air [kg]

    1. 2.3.1.2.1Background correction

    Notes on Division 2.3.1

    Textual amendments

    F1

    Substituted by Commission Delegated Regulation (EU) 2018/989 of 18 May 2018 amending and correcting Delegated Regulation (EU) 2017/654 supplementing Regulation (EU) 2016/1628 of the European Parliament and of the Council with regard to technical and general requirements relating to emission limits and type-approval for internal combustion engines for non-road mobile machinery (Text with EEA relevance).