OpenLegislation

Division 2.3.1.1.2 Calculation based on dilution ratio

United Kingdom

Original text. Later amendments are not shown.

The particulate emission over the cycle m PM [g] shall be calculated by means of equation (7-44):

m PM = m f m sep × m edf 1000 (7-44)

Where:

m f
  • particulate mass sampled over the cycle [mg]

  • m sep
  • mass of diluted exhaust gas passing the particulate collection filters [kg]

  • m edf
  • mass of equivalent diluted exhaust gas over the cycle [kg]

  • The total mass of equivalent diluted exhaust gas mass over the cycle m edf [kg] shall be determined by means of equation (7-45):

    m edf = 1 f × ∑ i = 1 N q m edf, i (7-45)

    With:

    F1 q m edf, i = q m ew, i × r d, i (7-46)
    r d, i = q m dew, i q m dew, i − q m dw, i (7-47)

    Where:

    qm edf, i
  • instantaneous equivalent diluted exhaust gas mass flow rate [kg/s]

  • qm ew, i
  • instantaneous exhaust gas mass flow rate on a wet basis [kg/s]

  • r d, i
  • instantaneous dilution ratio [-]

  • qm dew, i
  • instantaneous diluted exhaust gas mass flow rate on a wet basis [kg/s]

  • qm dw,i
  • instantaneous dilution air mass flow rate [kg/s]

  • ƒ
  • data sampling rate [Hz]

  • N
  • number of measurements [-]

  • Annotations

    Textual amendments

    F1

    Substituted by Commission Delegated Regulation (EU) 2018/989 of 18 May 2018 amending and correcting Delegated Regulation (EU) 2017/654 supplementing Regulation (EU) 2016/1628 of the European Parliament and of the Council with regard to technical and general requirements relating to emission limits and type-approval for internal combustion engines for non-road mobile machinery (Text with EEA relevance).