Division 2.4.1.2 Discrete-mode NRSC
United Kingdom
The specific emissions e gas [g/kWh] are calculated by means of equation (7-64):
| (7-64) |
where:
qm gas, i F1P i WFi F2N mode
mean emission mass flow rate for the mode i [g/h]
engine power for the mode i [kW] calculated by adding to the measured power P meas [kW] the power required to drive auxiliaries P AUX [kW] determined in accordance with equation (6-8) of Annex VI ( P i = P meas + P AUX )
weighting factor for the mode i [-]
number of modes in applicable discrete-mode NRSC
Annotations
Textual amendments
- F1
- F2