Division 1.1 Pursuant to point 1(b) of Article 3, the supplier shall enter into the product database the information as set out in Table 3, including when the light source is a part in a containing product.

United Kingdom

Original text. Later amendments are not shown.

Table 3

Product information sheet

changes to these items shall not be considered relevant for the purposes of point 4 of Article 4 of Regulation (EU) 2017/1369.

if the product database automatically generates the definitive content of this cell the supplier shall not enter these data.

‘-’: not applicable;

‘yes’: An equivalence claim involving the power of a replaced light source type may be given only:

  • for directional light sources, if the light source type is listed in Table 4 and if the luminous flux of the light source in a 90 ° cone (Φ90°) is not lower than the corresponding reference luminous flux in Table 4. The reference luminous flux shall be multiplied by the correction factor in Table 5. For LED light sources, it shall be in addition multiplied by the correction factor in Table 6;

  • for non-directional light sources, the claimed equivalent incandescent light source power (rounded to 1 W) shall be that corresponding in Table 7 to the luminous flux of the light source.

The intermediate values of both the luminous flux and the claimed equivalent light source power (rounded to the nearest 1 W) shall be calculated by linear interpolation between the two adjacent values.

‘-’: not applicable;

‘yes’: Claim that a LED light source replaces a fluorescent light source without integrated ballast of a particular wattage. This claim may be made only if:

  • the luminous intensity in any direction around the tube axis does not deviate by more than 25 % from the average luminous intensity around the tube; and

  • the luminous flux of the LED light source is not lower than the luminous flux of the fluorescent light source of the claimed wattage. The luminous flux of the fluorescent light source shall be obtained by multiplying the claimed wattage with the minimum luminous efficacy value corresponding to the fluorescent light source in Table 8; and

  • the wattage of the LED light source is not higher than the wattage of the fluorescent light source it is claimed to replace.

The technical documentation file shall provide the data to support such claims.

Supplier’s name or trade mark:
Supplier’s address f1 :
Model identifier:
Type of light source:
Lighting technology used:[HL/LFL T5 HE/LFL T5 HO/CFLni/other FL/HPS/MH/other HID/LED/OLED/mixed/other]Non-directional or directional:[NDLS/DLS]
Mains or non-mains:[MLS/NMLS]Connected light source (CLS):[yes/no]
Colour-tuneable light source:[yes/no]Envelope:[no/second/non-clear]
High luminance light source:[yes/no]
Anti-glare shield:[yes/no]Dimmable:[yes/only with specific dimmers/no]
Product parameters
ParameterValueParameterValue
General product parameters:
Energy consumption in on-mode (kWh/1 000 h)xEnergy efficiency class[A/B/C/D/E/F/G]f2
Useful luminous flux (Φuse), indicating if it refers to the flux in a sphere (360°), in a wide cone (120°) or in a narrow cone (90°)x in [sphere/wide cone/narrow cone]Correlated colour temperature, rounded to the nearest 100 K, or the range of correlated colour temperatures, rounded to the nearest 100 K, that can be set[x/x…x]
On-mode power (Pon), expressed in Wx,xStandby power (Psb), expressed in W and rounded to the second decimalx,xx
Networked standby power (Pnet) for CLS, expressed in W and rounded to the second decimalx,xxColour rendering index, rounded to the nearest integer, or the range of CRI-values that can be set[x/x…x]
Outer dimensions without separate control gear, lighting control parts and non-lighting control parts, if any (millimetre)HeightxSpectral power distribution in the range 250 nm to 800 nm, at full-load[graphic]
Widthx
Depthx
Claim of equivalent powerf3 [yes/-]If yes, equivalent power (W)x
Chromaticity coordinates (x and y)

0,xxx

0,xxx

Parameters for directional light sources:
Peak luminous intensity (cd)xBeam angle in degrees, or the range of beam angles that can be set[x/x…x]
Parameters for LED and OLED light sources:
R9 colour rendering index valuexSurvival factorx,xx
the lumen maintenance factorx,xx
Parameters for LED and OLED mains light sources:
displacement factor (cos φ1)x,xxColour consistency in McAdam ellipsesx
Claims that an LED light source replaces a fluorescent light source without integrated ballast of a particular wattage.[yes/-]f4 If yes then replacement claim (W)x
Flicker metric (Pst LM)x,xStroboscopic effect metric (SVM)x,x

Table 4

Reference luminous flux for equivalence claims

Extra-low voltage reflector type
TypePower (W)Reference Φ90° (lm)
MR11 GU420160
35300
MR16 GU 5.320180
35300
50540
AR11135250
50390
75640
100785
Mains-voltage blown glass reflector type
TypePower (W)Reference Φ90° (lm)
R50/NR502590
40170
R63/NR6340180
60300
R80/NR8060300
75350
100580
R95/NR9575350
100540
R125100580
1501 000
Mains-voltage pressed glass reflector type
TypePower (W)Reference Φ90° (lm)
PAR162090
25125
35200
50300
PAR2035200
50300
75500
PAR2550350
75550
PAR30S50350
75550
100750
PAR3650350
75550
100720
PAR3860400
75555
80600
100760
120900

Table 5

Multiplication factors for lumen maintenance

Light source typeLuminous flux multiplication factor
Halogen light sources1
Fluorescent light sources1,08
LED light sources

1 + 0,5 × (1 - LLMF)

where LLMF is the lumen maintenance factor at the end of the declared lifetime

Table 6

Multiplication factors for LED light sources

LED light source beam angleLuminous flux multiplication factor
20° ≤ beam angle1
15° ≤ beam angle < 20°0,9
10° ≤ beam angle < 15°0,85
beam angle < 10°0,8

Table 7

Equivalence claims for non-directional light sources

Rated light source luminous flux Φ (lm)Claimed equivalent incandescent light source power (W)
13615
24925
47040
80660
1 05575
1 521100
2 452150
3 452200

Table 8

Minimum efficacy values for T8 and T5 light sources

T8 (26 mm Ø)T5 (16 mm Ø)High EfficiencyT5 (16 mm Ø)High Output
Claimed equivalent power (W)Minimum luminous efficacy (lm/W)Claimed equivalent power (W)Minimum luminous efficacy (lm/W)Claimed equivalent power (W)Minimum luminous efficacy (lm/W)
156314862473
187521903979
257628934988
308035945482
36938077
3887
5890
7089

For light sources that can be tuned to emit light at full-load with different characteristics, the values of parameters that vary with these characteristics shall be reported at the reference control settings.

If the light source is no longer placed on the EU market, the supplier shall put in the product database the date (month, year) when the placing on the EU market stopped.

Annotations

Footnotes

f1

changes to these items shall not be considered relevant for the purposes of point 4 of Article 4 of Regulation (EU) 2017/1369.

f2

if the product database automatically generates the definitive content of this cell the supplier shall not enter these data.

f3

‘-’: not applicable;

‘yes’: An equivalence claim involving the power of a replaced light source type may be given only:

  • for directional light sources, if the light source type is listed in Table 4 and if the luminous flux of the light source in a 90 ° cone (Φ90°) is not lower than the corresponding reference luminous flux in Table 4. The reference luminous flux shall be multiplied by the correction factor in Table 5. For LED light sources, it shall be in addition multiplied by the correction factor in Table 6;

  • for non-directional light sources, the claimed equivalent incandescent light source power (rounded to 1 W) shall be that corresponding in Table 7 to the luminous flux of the light source.

The intermediate values of both the luminous flux and the claimed equivalent light source power (rounded to the nearest 1 W) shall be calculated by linear interpolation between the two adjacent values.

f4

‘-’: not applicable;

‘yes’: Claim that a LED light source replaces a fluorescent light source without integrated ballast of a particular wattage. This claim may be made only if:

  • the luminous intensity in any direction around the tube axis does not deviate by more than 25 % from the average luminous intensity around the tube; and

  • the luminous flux of the LED light source is not lower than the luminous flux of the fluorescent light source of the claimed wattage. The luminous flux of the fluorescent light source shall be obtained by multiplying the claimed wattage with the minimum luminous efficacy value corresponding to the fluorescent light source in Table 8; and

  • the wattage of the LED light source is not higher than the wattage of the fluorescent light source it is claimed to replace.

The technical documentation file shall provide the data to support such claims.