OpenLegislation

Division 1 General conditions for testing:

United Kingdom

Original text. Later amendments are not shown.

  1. (a)

    the ambient conditions shall correspond to Set 1, except for ice-cream freezers and gelato-scooping cabinets which shall be tested in ambient conditions corresponding to Set 2, as set out in Table 3;

  2. (b)

    where a compartment can be set to different temperatures, it shall be tested at the lowest operating temperature;

  3. (c)

    refrigerated vending machines with compartments with variable volumes shall be tested with the net volume of the compartment with the highest operating temperature adjusted to its minimum net volume;

  4. (d)

    for beverage coolers, the specified cooling speed shall be according to the half reload recovery time.

    Table 3

    Ambient conditions

    Dry bulb temperature, °CRelative humidity, %Dew point, °CWater vapour mass in dry air, g/kg
    Set 1256016,712,0
    Set 2305520,014,8