OpenLegislation

Division 4.1.1 Use-specific instructions for use

United Kingdom

Original text. Later amendments are not shown.

For use only on visibly clean surfaces. Cleaning prior to disinfection is required. Physically remove contaminants from the surface before disinfection using a suitable cleanroom wipe and a recommended wiping technique for optimum contamination control.

Spray directly onto a suitable cleanroom wipe. Use a wipe to distribute the liquid on the surface.

Ensure the surface is uniformly covered with the product and leave for the required contact time indicated to kill bacteria, fungi, yeast and bacterial spores.

Do not apply more than 50 ml/m2.

Leave for required contact time and wipe to dry afterwards.

For use at room temperature (20 ± 2 °C).

Suitable cleanroom wipe materials should be used in order to minimise interaction with the product.

Used wipes must be disposed in a closed container.