Paragraph 4 Apparatus
Northern Ireland Not yet in force
4.1
250 ml conical flasks with ground glass or PTFE stoppers.
4.2
Stoppered centrifuge tubes.
4.3
Gas chromatograph with flame ionisation detector.
4.4
Column:
-
either (i) 1.5 m glass column (4 mm internal diameter) packed with 5% OV17 on Gas Chrom Q, 80-100 mesh,
-
or (ii) 1.5 m glass column (4 mm internal diameter) packed with 5% Carbowax 20M-TPA on Diatomite C-AAW, 80-100 mesh.
4.5
Water bath: hotplate stirrer on which is placed a 2,000 ml beaker (or suitable vessel) containing water maintained at 40-50°C.