Paragraph 2
United Kingdom
For cushions with primary covers the test specimen shall be made up of filling, the primary cover and standard fabric as in Schedule 1 Part I, paragraph 2. Where the filling is loose, it shall be packed as set out in Schedule 1 Part II, paragraph 3. The test procedure using ignition source 2 shall be as specified in BS 5852: Part 2. If smouldering or flaming failure against the criteria of clause 4 of BS 5852: Part 2 has not occurred or has occurred only by way of damage exceeding the limits defined in clause 4(1)(e), 4(1)(f) and 4(2)(f) the composite cushion filling passes the ignitability test.
Notes on Schedule 2
Commencement
- I1
Sch. 2 in force at 1.11.1988, see reg. 1(2)(a)