Paragraph 1 F1
Values used for calculation of electricity from cogeneration must be determined on the basis of the expected or actual operation of the unit under normal conditions of use. For micro-cogeneration units the calculation may be based on certified values.
Electricity production from cogeneration must be considered equal to total annual electricity production of the unit measured at the outlet of the main generators—
in cogeneration units of the types referred to in paragraph 2(b) and (d) to (h) with an annual overall efficiency at a level of at least 75%; and
in cogeneration units of the types referred to in paragraph 2(a) and (c) with an annual overall efficiency at a level of at least 80%.
In cogeneration units with an annual overall efficiency below the value referred to in sub-paragraph (2)(a) or with an annual overall efficiency below the value referred to in sub-paragraph (2)(b) cogeneration is calculated according to the following formula—
where—
ECHP is the amount of electricity from cogeneration;
C is the power-to-heat ratio;
HCHP is the amount of useful heat from cogeneration (calculated for this purpose as total heat production minus any heat produced in separate boilers or by live steam extraction from the steam generator before the turbine).
For the purposes of sub-paragraph (3), the calculation of electricity from cogeneration must be based on the actual power-to-heat ratio. If the actual power-to-heat ratio of a cogeneration unit is not known, the following default values may be used for units of types (a), (b), (c), (d) and (e) referred to in paragraph 2 provided that the calculated cogeneration electricity is less or equal to total electricity production of the unit—
| Type of unit | Default power to heat ratio, C |
|---|---|
| Combined cycle gas turbine with heat recovery | 0.95 |
| Steam back pressure turbine | 0.45 |
| Steam condensing extraction turbine | 0.45 |
| Gas turbine with heat recovery | 0.55 |
| Internal combustion engine | 0.75 |
If a share of the energy content of the fuel input to the cogeneration process is recovered in chemicals and recycled this share can be subtracted from the fuel input before calculating the overall efficiency used in sub-paragraphs (2) and (3).
The power-to-heat ratio when operating in cogeneration mode at a capacity lower than full cogeneration is the ratio of electricity to useful heat determined using operational data of the specific unit.
The competent authority may use other reporting periods than one year for the purpose of the calculations according to sub-paragraphs (2) and (3).