Schedule THE AMENDMENTS TO REGULATIONS

Changes not yet applied. Later legislation changes this provision in ways not yet written into the text below:

1234
Regulation to be amendedSubject matter of measurementPresent measurementMeasurement to be substituted
The Blasting (Castings and other Articles) Special Regulations 1949
Regulation 12(3)Minimum rate at which clean air to be supplied to helmetsix cubic feet per minute170 litres per minute
Regulation 17(2)Minimum distance from blasting enclosuretwenty feet6 metres
The Iron and Steel Foundries Regulations 1953
Regulation 5(a) Distance from spout of cupola or furnace within which work not to be carried outtwelve feet4 metres
(b) Distance from ladle within which work not to be carried outeight feet2.4 metres
Regulation 6(1)(c)Minimum width of certain gangwaysthree feet920 millimetres
Regulation 6(1)(d)(i)Minimum amount gangways shall be wider than overall width of ladletwo feet600 millimetres
Regulation 6(1)(d)(ii)Minimum width of certain gangwaysthree feet920 millimetres
Regulation 6(1)(d)(iii)Minimum width of certain gangwaysfour feet1.2 metres
Regulation 6(1)(d)(iv)Minimum width of certain gangwayssix feet1.8 metres
Regulation 6(2)(a)(iii)Minimum width of pouring aisleseighteen inches460 millimetres
Regulation 6(2)(b)(ii)Minimum width of pouring aisleseighteen inches460 millimetres
Non-Ferrous Metals (Melting and Founding) Regulations 1962
Regulation 2(2)Definition of “degrees”degrees Fahrenheitdegrees Celsius
Regulation 10(1)(a)(a) Minimum width of pouring aisleseighteen inches460 millimetres
(b) Minimum height of moulds above floortwenty inches510 millimetres
(c) Minimum width of pouring aisles when moulds alongside are more than minimum height above the floortwenty-four inches600 millimetres
Regulation 10(1)(b)Minimum width of pouring aislesthirty inches760 millimetres
Regulation 10(2)(a)Minimum width of certain gangwaysthree feet920 millimetres
Regulation 10(2)(c)(i)Minimum amount gangways shall be wider than overall width of ladletwo feet600 millimetres
Regulation 10(2)(c)(ii)Minimum width of certain gangwaysfour feet1.2 metres
Regulation 10(2)(c)(iii)Minimum width of certain gangwayssix feet1.8 metres
Regulation 14(a) Minimum room temperaturefifty degrees10 degrees
(b) Maximum outside temperature at which proviso appliesthirty degrees−1 degree
(c) Minimum amount by which room temperature should exceed outside temperaturetwenty degrees11 degrees
Regulation 15(2)(c)Maximum interval at which taps or jets to be fitted to troughtwo feet600 millimetres
Regulation 15(3)(a)(a) Definition of “unit” in terms of length of troughtwo feet600 millimetres
(b) Definition of “unit” in terms of section of circumference of troughtwo feet600 millimetres
Regulation 15(3)(c)Minimum internal measurement of basin or other receptaclefour feet1.2 metres
Regulation 17Minimum height to which walls are to be cleanedfourteen feet4.2 metres