Paragraph 2 Detailed offshore design parametersI1
England and Wales
The total number of wind turbine generators comprised in the authorised project must not exceed 231 and a total rotor swept area of 8.8 square kilometres.
Subject to sub-paragraph (3), each wind turbine generator forming part of the authorised project must not—
exceed a height of 325 metres when measured from LAT to the tip of the vertical blade;
exceed a rotor diameter of 265 metres;
be less than 41.8 metres from LAT to the lowest point of the rotating blade; and
be less than one kilometre from the nearest wind turbine generator in all directions.
The reference in sub-paragraph (2)(d) to the location of a wind turbine generator is a reference to the centre point of that wind turbine generator.
Wind turbine generator foundation structures forming part of the authorised scheme must be one of the following foundation options: monopile foundation, mono suction bucket foundation, jacket foundation or gravity base foundation.
No wind turbine generator—
jacket foundations employing pin piles forming part of the authorised project shall have a pin pile diameter of greater than four metres; and
monopile foundation forming part of the authorised project shall have a diameter greater than 15 metres.
The total seabed footprint area for wind turbine generator foundations must not exceed—
435,660 square metres excluding scour protection; and
1,623,182 square metres including scour protection.
Annotations
Commencement
- I1
Sch. 1 Pt. 3 para. 2 in force at 22.1.2021, see art. 1
Notes on the whole SI
Textual amendments
- F1
Preamble: bracket omitted (21.5.2021) by virtue of The Hornsea Three Offshore Wind Farm (Correction) Order 2021 (S.I. 2021/599), art. 1(2), Sch.