Paragraph 1 Design parametersI1
England and Wales
The total number of wind turbine generators comprised in the authorised project must not exceed 231 and a total rotor swept area of 8.8 square kilometres.
Subject to paragraph (3), each wind turbine generator forming part of the authorised project must not—
exceed a height of 325 metres when measured from LAT to the tip of the vertical blade;
exceed a rotor diameter of 265 metres;
be less than 41.8 metres from LAT to the lowest point of the rotating blade; and
be less than one kilometre from the nearest wind turbine generator in all directions.
The reference in sub-paragraph 1(2)(d) to the location of a wind turbine generator is a reference to the centre point of that wind turbine generator.
Wind turbine generator foundation structures forming part of the authorised scheme must be one of the following foundation options: monopile foundation, mono suction bucket foundation, jacket foundation or gravity base foundation.
No wind turbine generator—
jacket foundation employing pin piles forming part of the authorised project shall have a pin pile diameter of greater than four metres; and
monopile foundation forming part of the authorised project shall have a diameter greater than 15 metres.
The total seabed footprint area for wind turbine generator foundations must not exceed—
435,660 square metres excluding scour protection; and
1,623,182 square metres including scour protection.
The volume of scour protection material for wind turbine generator foundations must not exceed 2,375,044 cubic metres.